How to install floor panel and electric boiler

Installing Styrofoam panel

  • Remove foreign substances and keep the floor clean, and then install the Styrofoam panels.
  • Prefab Styrofoam panels (1.5T) are designed to provide paths of PVC hoses; very simple and easy to install.
  • The finished edges or area to be fixed shall only be fixed with adhesive tape.
  • * Cut the Styrofoam panel to adequate size on the corners or into a non-standard shape.

Installing Styrofoam panel

Installing heat dissipation plates on the floor

  • Install the prefab heat dissipation plate (SGL steel sheet, 0.5%) on the Styrofoam panels (1.5%) one by one.
  • Do not install the heat dissipation plates on round-finished corners.

Installing heat dissipation plates on the floor

Installing PVC hose (10ø)

  • Insert the PVC hoses into the rolls on the groove of the hot water panels. Clear distinction shall be made between the inlet hose and outlet hose.
  • The PVC hose (10ø) is very flexible and very easy to connect on bended sections.
  • Never make connection between the hoses.

Installing PVC hose (10ø)

Installing cover of the heat dissipation plate

  • The heat dissipation plate cover is excellent in heat transfer (heat conductivity) and heat storage (thermal storage function) to reduce energy consumption.
  • Installing covers of standard size tightly to each other ensures finishing.
  • You can cut the cover for finishing non-standard areas.
  • Installing the heat dissipation plates (function of flat stone for hypocaust) completes the installation work.

Installing cover of the heat dissipation plate

Work on connections of electric boiler

  • Insert the PVC hose (10ø) for hot water into the bottom of the electric boiler, and then fasten the connection.
  • Connect the plug to the receptacle and fill the water tank of the boiler with water.
  • By supplying water to the electric boiler until the warning indicator is turned off, installation of the boiler is completed.

Work on connections of electric boiler

Installing interior materials

  • Any interior materials are allowed for finishing.
  • (e.g., floor covering, deco-time and reinforced flooring) Floor covering is laid on the heat dissipation plate cover.
  • Finishing the floor covering completes installation.
  • Now, all of the installing procedures are completed.

Installing interior materials